X-ray response of CdZnTe detectors grown by the vertical Bridgmantechnique:Energy, temperature and high flux effects

Risultato della ricerca: Articlepeer review

36 Citazioni (Scopus)

Abstract

Nowadays, CdZnTe (CZT) is one of the key materials for the development of room temperature X-ray and gamma ray detectors and great efforts have been made on both the device and the crystal growth technologies. In this work, we present the results of spectroscopic investigations on new boron oxide encapsulated vertical Bridgman (B-VB) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Several detectors, with the same electrode layout (gold electroless contacts) and different thicknesses (1 and 2.5 mm), were realized: the cathode is a planar electrode covering the detector surface (4.1×4.1 mm2), while the anode is a central electrode (2×2 mm2) surrounded by a guard-ring electrode. The detectors are characterized by electron mobility-lifetime product (µeτe) values ranging between 0.6 and 1·10−3 cm2/V and by low leakage currents at room temperature and at high bias voltages (38 nA/cm2 at 10000 V/cm). The spectroscopic response of the detectors to monochromatic X-ray and gamma ray sources (109Cd, 241Am and 57Co), at different temperatures and fluxes (up to 1 Mcps), was measured taking into account the mitigation of the effects of incomplete charge collection, pile-up and high flux radiation induced polarization phenomena. A custom-designed digital readout electronics, developed at DiFC of University of Palermo (Italy), able to perform a fine pulse shape and height analysis even at high fluxes, was used. At low rates (200 cps) and at room temperature (T=25 °C), the detectors exhibit an energy resolution FWHM around 4% at 59.5 keV, for comparison an energy resolution of 3% was measured with Al/CdTe/Pt detectors by using the same electronics (A250F/NF charge sensitive preamplifier, Amptek, USA; nominal ENC of 100 electrons RMS). At high rates (750 kcps), energy resolution values of 7% and 9% were measured, with throughputs of 2% and 60% respectively. No radiation polarization phenomena were observed at room temperature up to 1 Mcps (241Am source, 60 keV), while a detector collapse characterizes the samples at T<10 °C. Comparison with two traveling heater method (THM) grown CZT detectors (REDLEN, Canada), fabricated with the same electrode layout, is also presented. These activities are in the framework of an Italian research project on the development of energy-resolved photon counting (ERPC) systems for high flux energy-resolved X-ray imaging.
Lingua originaleEnglish
pagine (da-a)1-12
Numero di pagine12
RivistaNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT
Volume835
Stato di pubblicazionePublished - 2016

All Science Journal Classification (ASJC) codes

  • ???subjectarea.asjc.3100.3106???
  • ???subjectarea.asjc.3100.3105???

Fingerprint

Entra nei temi di ricerca di 'X-ray response of CdZnTe detectors grown by the vertical Bridgmantechnique:Energy, temperature and high flux effects'. Insieme formano una fingerprint unica.

Cita questo