Why laparoscopists may opt for three-dimensional view: a summary of the full HTA report on 3D versus 2D laparoscopy by S.I.C.E. (Società Italiana di Chirurgia Endoscopica e Nuove Tecnologie)

Gianfranco Cocorullo, Emauele Lettieri, Umberto Nocco, Domenico Marchi, Emanuela Foglia, Chiara Gerardi, Lucrezia Ferrario, Michele Tringali, Gianfranco Silecchia, Gianfranco Cocorullo, Nereo Vettoretto, Giuseppe Portale, Giuseppe Currò, Alberto Arezzo, Roberto Cirocchi, Gabriele Anania, Mario Morino, Andrea Valeri, Micaela Piccoli, Giuseppe Portale

Risultato della ricerca: Articlepeer review

25 Citazioni (Scopus)

Abstract

Background: Three-dimensional view in laparoscopic general, gynaecologic and urologic surgery is an efficient, safe and sustainable innovation. The present paper is an extract taken from a full health technology assessment report on three-dimensional vision technology compared with standard two-dimensional laparoscopic systems. Methods: A health technology assessment approach was implemented in order to investigate all the economic, social, ethical and organisational implications related to the adoption of the innovative three-dimensional view. With the support of a multi-disciplinary team, composed of eight experts working in Italian hospitals and Universities, qualitative and quantitative data were collected, by means of literature evidence, validated questionnaire and self-reported interviews, applying a final MCDA quantitative approach, and considering the dimensions resulting from the EUnetHTA Core Model. Results: From systematic search of literature, we retrieved the following studies: 9 on general surgery, 35 on gynaecology and urology, both concerning clinical setting. Considering simulated setting we included: 8 studies regarding pitfalls and drawbacks, 44 on teaching, 12 on surgeons’ confidence and comfort and 34 on surgeons’ performances. Three-dimensional laparoscopy was shown to have advantages for both the patients and the surgeons, and is confirmed to be a safe, efficacious and sustainable vision technology. Conclusions: The objective of the present paper, under the patronage of Italian Society of Endoscopic Surgery, was achieved in that there has now been produced a scientific report, based on a HTA approach, that may be placed in the hands of surgeons and used to support the decision-making process of the health providers.
Lingua originaleEnglish
pagine (da-a)2986-2993
Numero di pagine8
RivistaSurgical Endoscopy
Volume32
Stato di pubblicazionePublished - 2018

All Science Journal Classification (ASJC) codes

  • ???subjectarea.asjc.2700.2746???

Fingerprint

Entra nei temi di ricerca di 'Why laparoscopists may opt for three-dimensional view: a summary of the full HTA report on 3D versus 2D laparoscopy by S.I.C.E. (Società Italiana di Chirurgia Endoscopica e Nuove Tecnologie)'. Insieme formano una fingerprint unica.

Cita questo