TY - CONF
T1 - Towards a conceptual mathematical tool linking physical and biological processes for a reduction of ghg emissions from an mb-mbr plant
AU - Mannina, Giorgio
AU - Di Trapani, Daniele
AU - Capodici, Marco
AU - Cosenza, Alida
PY - 2016
Y1 - 2016
N2 - The current study explores the influence of the air flow rate on greenhouse gas (GHG) emissions (direct and indirect), the operational costs (OCs), the effluent quality index (EQI) and effluent fines (EF). An University Cape Town (UCT) moving bed (MB) membrane bioreactor (MBR) pilot plant has been considered as case study where the influence of the air flow rate on the biological and physical processes has been analyzed. Constitutive relationships between the air flow rate and some performance indicators (i.e., EQI, OCs, direct and indirect GHG emissions) have been identified. Results showed that the EQI increases at low flow rate likely due to the dissolved oxygen (DO) limitation in the biological processes. Direct GHGs are influenced by air flow exponentially increasing with the increase of the air flow due to the anoxic N2O contribution. Irreversible membrane fouling reduce from 98% to 85% with the increasing of the air flow rate from 0.57 m3 h-1 to 2.56 m3 h- 1. However, the increase of the air flow rate leads to the increase of the N2O-N flux emitted from the MBR (from 40% to 80%). In order to establish a mathematical tool to reduce GHG emissions maintaining good effluent quality, results suggest of adopting a relationship based on a “multiple objective”.
AB - The current study explores the influence of the air flow rate on greenhouse gas (GHG) emissions (direct and indirect), the operational costs (OCs), the effluent quality index (EQI) and effluent fines (EF). An University Cape Town (UCT) moving bed (MB) membrane bioreactor (MBR) pilot plant has been considered as case study where the influence of the air flow rate on the biological and physical processes has been analyzed. Constitutive relationships between the air flow rate and some performance indicators (i.e., EQI, OCs, direct and indirect GHG emissions) have been identified. Results showed that the EQI increases at low flow rate likely due to the dissolved oxygen (DO) limitation in the biological processes. Direct GHGs are influenced by air flow exponentially increasing with the increase of the air flow due to the anoxic N2O contribution. Irreversible membrane fouling reduce from 98% to 85% with the increasing of the air flow rate from 0.57 m3 h-1 to 2.56 m3 h- 1. However, the increase of the air flow rate leads to the increase of the N2O-N flux emitted from the MBR (from 40% to 80%). In order to establish a mathematical tool to reduce GHG emissions maintaining good effluent quality, results suggest of adopting a relationship based on a “multiple objective”.
KW - Wastewater treatment
KW - global warming potential
KW - membrane
KW - moving bed biofilm reactors
KW - Wastewater treatment
KW - global warming potential
KW - membrane
KW - moving bed biofilm reactors
UR - http://hdl.handle.net/10447/180714
M3 - Other
SP - 1
EP - 13