Repeatability of exhaled breath fingerprint collected by a modern sampling system in asthmatic and healthy children

Giuliana Ferrante, Marco Santonico, Salvatore Fasola, Simone Grasso, Alessandro Zompanti, Raffaele Antonelli Incalzi, Anna Sabatini, Stefania La Grutta, Raffaele Antonelli Incalzi

Risultato della ricerca: Articlepeer review

6 Citazioni (Scopus)

Abstract

E-noses provide potential non-invasive metabolic biomarkers for diagnosing and monitoring pulmonary diseases. The primary aim of the present study was to assess the within-day and between-day repeatability of a modern breath sampling system (Pneumopipe® plus an array of e-nose sensors) in asthmatic and healthy children. The secondary aim was to compare the repeatability of the breath sampling system, spirometry and exhaled nitric oxide (eNO). Fifteen children (age 6-11 years) with asthma and thirty healthy children matched by age and gender (1:2 allocation) were recruited; of them, three healthy children did not complete the study. All measurements were collected twice during the baseline visit, 30 min apart, and once during the final visit, after 7 d. Repeatability was assessed through the intra-cluster correlation coefficient (ICC), and a significance test was performed to detect an at least 'fair' repeatability (ICC > 0.2). In asthmatic children, the within-day (0-30 min) ICCs for e-nose sensors (8 sensors × 4 desorption temperatures) ranged from 0.24 to 0.84 (median 0.57, IQR 0.47-0.71), while the between-day (0-7 d) ICCs ranged from 0.25 to 0.83 (median 0.66, IQR 0.55-0.72). In healthy children, the within-day ICCs for e-nose sensors ranged from 0.29 to 0.85 (median 0.58, IQR 0.49-0.63), while the between-day ICCs ranged from 0.33 to 0.82 (median 0.55, IQR 0.49-0.63). In both groups, most of the within-day and between-day ICCs for e-nose sensors were statistically significant. Moreover, the within-day and between-day ICCs for all spirometry parameters and eNO were significant and similar to those of the most reliable sensors. The modern breath sampling system showed more than acceptable within-day and between-day repeatability, in both asthmatic and healthy children. The present study was registered on the central registration system ClinicalTrials.gov (ID: NCT03025061).
Lingua originaleEnglish
Numero di pagine10
RivistaJournal of Breath Research
Volume13
Stato di pubblicazionePublished - 2019

All Science Journal Classification (ASJC) codes

  • Pulmonary and Respiratory Medicine

Fingerprint Entra nei temi di ricerca di 'Repeatability of exhaled breath fingerprint collected by a modern sampling system in asthmatic and healthy children'. Insieme formano una fingerprint unica.

Cita questo