T1 - Multislice multiecho T2* cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload.
AU - Midiri, Massimo
AU - De Marchi, Daniele
AU - Pepe, Alessia
AU - Landini, Luigi
AU - Positano, Vincenzo
AU - Santarelli, Maria Filomena
AU - Maggio, Aurelio
AU - Lombardi, Massimo
AU - Pepe, Alessia
AU - Cracolici, Eliana
AU - Sorrentino, Fortunato
PY - 2006
Y1 - 2006
N2 - Purpose: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r = 0.98), 5.5% (r = 0.98), and 4.7% (r = 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%), heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95, P < 0.0001). Conclusion: Multislice multiecho T2* MRI provides a non-invasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value.
AB - Purpose: To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods: T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results: For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r = 0.98), 5.5% (r = 0.98), and 4.7% (r = 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%), heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95, P < 0.0001). Conclusion: Multislice multiecho T2* MRI provides a non-invasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value.
UR - http://hdl.handle.net/10447/10242
M3 - Article
SN - 1053-1807
VL - 23
SP - 662
EP - 668
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
ER -