TY - JOUR
T1 - Effect of Fibrin Sealant on Seroma Formation Post-Incisional Hernia Repair
AU - D'Orazio, Beatrice
AU - Bonventre, Sebastiano
AU - Cudia, Bianca Maria
AU - Geraci, Girolamo
AU - Famà, Fausto
AU - Di Vita, Gaetano
AU - Sciume, Carmelo
AU - Corbo, Giovanni
AU - Terranova, Gloria Maria
PY - 2020
Y1 - 2020
N2 - Background: Development of seroma after incisional hernia repair is a common complication. Our study aims to compare the outcomes of sublay incisional hernia repairs with or without spray instillation of fibrin glue. Methods: We enrolled fifty patients undergoing incisional hernia repair. In all patients a suction drain was placed in the subcutaneous space. In one group (FG) 4 ml fibrin glue was instilled in the subcutaneous space. In the control group (C) patients did not receive any prevention measure. Wounds fluids were collected on post-operative day 1 (POD) and once daily until drain removal. All patients were followed up by ultrasound on POD 15, 20, 40, 60. Results: Drain fluid production, even if in significantly greater amount in the C group (p 0.01) as compared with the FG group, decreased after POD 1 in both groups. Drain was removed on POD-5 in 80% of FG patients and in 36% of C patients (p 0.01). No infective or bleeding complications were detected. In group FG average hospital stay was of 5.5 ÃÂ+- 2 days versus 7.1 +- 1.5 days in group C (p 0.01). At ultrasounds examination, seroma development was similar among two groups. Conclusions: Spray instillation of fibrin glue during the surgical repair reduces amount of drained fluid and hospital stay without increasing surgical complications. However, seroma occurrence was not significantly reduced.
AB - Background: Development of seroma after incisional hernia repair is a common complication. Our study aims to compare the outcomes of sublay incisional hernia repairs with or without spray instillation of fibrin glue. Methods: We enrolled fifty patients undergoing incisional hernia repair. In all patients a suction drain was placed in the subcutaneous space. In one group (FG) 4 ml fibrin glue was instilled in the subcutaneous space. In the control group (C) patients did not receive any prevention measure. Wounds fluids were collected on post-operative day 1 (POD) and once daily until drain removal. All patients were followed up by ultrasound on POD 15, 20, 40, 60. Results: Drain fluid production, even if in significantly greater amount in the C group (p 0.01) as compared with the FG group, decreased after POD 1 in both groups. Drain was removed on POD-5 in 80% of FG patients and in 36% of C patients (p 0.01). No infective or bleeding complications were detected. In group FG average hospital stay was of 5.5 ÃÂ+- 2 days versus 7.1 +- 1.5 days in group C (p 0.01). At ultrasounds examination, seroma development was similar among two groups. Conclusions: Spray instillation of fibrin glue during the surgical repair reduces amount of drained fluid and hospital stay without increasing surgical complications. However, seroma occurrence was not significantly reduced.
UR - http://hdl.handle.net/10447/475708
M3 - Article
VL - 115
SP - 767
EP - 774
JO - Chirurgia (Romania)
JF - Chirurgia (Romania)
SN - 1221-9118
ER -