Abstract
In this paper, a high temperature axial flux (HTSAF) generator is presented. In this generator the excitation of the generator isobtained by using some high temperature superconducting magnets. In order to reduce the negative effects of vibrations, the excitationis located on the stationary part of the generator. Starting, running and endurance tests of the machine are presented.
Lingua originale | English |
---|---|
Numero di pagine | 4 |
Rivista | IEEE Transactions on Magnetics |
Volume | 13 |
Stato di pubblicazione | Published - 2013 |
All Science Journal Classification (ASJC) codes
- ???subjectarea.asjc.2500.2504???