TY - JOUR
T1 - Deep SSI after mesh-mediated groin hernia repair: Management and outcome in an Emergency Surgery Department
AU - Salamone, Giuseppe
AU - Gulotta, Gaspare
AU - Profita, Giuseppe
AU - Cocorullo, Gianfranco
AU - Tutino, Roberta
AU - Licari, Leo
AU - Gullo, Roberto
AU - Raspanti, null
AU - Falco, Nicolò
AU - Campanella, null
AU - De Marco, null
AU - Profita, Giuseppe
AU - Cocorullo, Gianfranco
AU - Augello, null
AU - Tutino, null
AU - Licari, Leo
AU - Porrello, null
AU - Gulotta, null
AU - Salamone, null
AU - Raspanti, Cristina
AU - Augello, Giuseppe
AU - Falco, Nicolo'
AU - De Marco, Paolino
AU - Gullo, Roberto
AU - Campanella, Sofia
PY - 2017
Y1 - 2017
N2 - Aim. Mesh-mediated groin hernia repair is considered the goldstandard procedure. It has low recurrence rate. Rarely a deep Surgical Site Infection (SSI) is seen when a synthetic prosthesis is used. Case report. We describe a rare case of bilateral deep SSI after mesh- mediated groin hernia repair. Diagnosis was performed through the physical examination and radiological exams. Microbiological samples identified a methicillin-resistant Staphylococcus aureus responsible of the infection. Target therapy was performed and re-operation performed in order to remove the infected prosthesis and to apply a biological one to create the fibrous scaffold. During follow-up time, right side recurrence was observed. Tru-cut biopsy of fascia was obtained in order to identify the responsible of the recurrence. Conclusion. Combination of antibiotic therapy and surgical reoperation seems to be the correct way to approach the deep SSI after mesh- mediated groin hernia repair. The use of biological mesh after synthetic removal seems to improve the final outcome.
AB - Aim. Mesh-mediated groin hernia repair is considered the goldstandard procedure. It has low recurrence rate. Rarely a deep Surgical Site Infection (SSI) is seen when a synthetic prosthesis is used. Case report. We describe a rare case of bilateral deep SSI after mesh- mediated groin hernia repair. Diagnosis was performed through the physical examination and radiological exams. Microbiological samples identified a methicillin-resistant Staphylococcus aureus responsible of the infection. Target therapy was performed and re-operation performed in order to remove the infected prosthesis and to apply a biological one to create the fibrous scaffold. During follow-up time, right side recurrence was observed. Tru-cut biopsy of fascia was obtained in order to identify the responsible of the recurrence. Conclusion. Combination of antibiotic therapy and surgical reoperation seems to be the correct way to approach the deep SSI after mesh- mediated groin hernia repair. The use of biological mesh after synthetic removal seems to improve the final outcome.
UR - http://hdl.handle.net/10447/244737
M3 - Article
SN - 0391-9005
VL - 38
SP - 41
EP - 45
JO - Giornale di Chirurgia
JF - Giornale di Chirurgia
ER -