Contaminant Intrusion through Leaks in Water Distribution System: Experimental Analysis

Valeria Puleo, Vincenza Notaro, Chiara Maria Fontanazza, Gabriele Freni, Chiara M. Fontanazza, Valeria Puleo, Vincenza Notaro, Paolo Nicolosi, Gabriele Freni

Risultato della ricerca: Articlepeer review

17 Citazioni (Scopus)

Abstract

This paper presents the results of experimental tests on the intrusion of contaminant through pipe cracks in water distribution network resulting from low/negative pressures. The tests were carried out on a looped distribution network at the University of Enna and were performed first producing a pressure transient that causes negative pressures then reproducing intermittent supply. A soluble contaminant was added to the water volume in the network through a pipe crack. Sampling of water volume was carried out in two nodes of the network and the contaminant concentrations were measured. It was showed that: the contaminant was drawn in and transported, in the first set of tests; the contaminant was carried through the network to the point-of-use when the pipes become completely full and the distribution system was in steady state conditions, in the second, and that the concentrations was higher than in the first set of tests
Lingua originaleEnglish
pagine (da-a)426-433
Numero di pagine8
RivistaProcedia Engineering
Volume119
Stato di pubblicazionePublished - 2015

All Science Journal Classification (ASJC) codes

  • ???subjectarea.asjc.2200.2200???

Fingerprint

Entra nei temi di ricerca di 'Contaminant Intrusion through Leaks in Water Distribution System: Experimental Analysis'. Insieme formano una fingerprint unica.

Cita questo