Comparison in terms of TOF measurements between APD and SiPM for LiDAR applications

Risultato della ricerca: Paper

Abstract

We present an experimental comparison of two LiDAR systems, employing the SiPM and the APD as photodetectors, in terms of TOF measurements differing for the distance of the target and at different intensities of ambient light. The use of the APD represents the conventional approach, while the implementation of the SiPM is innovative. The performed measurements achieved very promising results, thus demonstrating the effectiveness of our LiDAR based on SiPM.
Lingua originaleEnglish
Stato di pubblicazionePublished - 2016

Fingerprint

photometers

Cita questo

@conference{cc9719f2b01e413da6bed4948c48ca0e,
title = "Comparison in terms of TOF measurements between APD and SiPM for LiDAR applications",
abstract = "We present an experimental comparison of two LiDAR systems, employing the SiPM and the APD as photodetectors, in terms of TOF measurements differing for the distance of the target and at different intensities of ambient light. The use of the APD represents the conventional approach, while the implementation of the SiPM is innovative. The performed measurements achieved very promising results, thus demonstrating the effectiveness of our LiDAR based on SiPM.",
author = "Alessandro Busacca and Gabriele Adamo",
year = "2016",
language = "English",

}

TY - CONF

T1 - Comparison in terms of TOF measurements between APD and SiPM for LiDAR applications

AU - Busacca, Alessandro

AU - Adamo, Gabriele

PY - 2016

Y1 - 2016

N2 - We present an experimental comparison of two LiDAR systems, employing the SiPM and the APD as photodetectors, in terms of TOF measurements differing for the distance of the target and at different intensities of ambient light. The use of the APD represents the conventional approach, while the implementation of the SiPM is innovative. The performed measurements achieved very promising results, thus demonstrating the effectiveness of our LiDAR based on SiPM.

AB - We present an experimental comparison of two LiDAR systems, employing the SiPM and the APD as photodetectors, in terms of TOF measurements differing for the distance of the target and at different intensities of ambient light. The use of the APD represents the conventional approach, while the implementation of the SiPM is innovative. The performed measurements achieved very promising results, thus demonstrating the effectiveness of our LiDAR based on SiPM.

UR - http://hdl.handle.net/10447/223100

M3 - Paper

ER -