Abstract
Present work deals with the topic of building integration of solar thermal collector (BIST) as a refurbishment measure. Such equipment, more than its main function as heating generator, plays a specific role as a building component (envelope finishes, thermal insulation layer, roof cover etc). Consequently, from a heat transfer point of view, an integrated component affects twice the global building balance: supporting the thermal plant (i.e. providing heat for final uses) and modifying the wall heat-transfer pattern (i.e. reducing thermal losses). In turn, the collector performance itself is influenced by the wall structure (back losses reduction). Present work proposes a method for evaluating the yearly performance of a low cost BIST by means of a Trnsys model on a reference building. This model arises from previous studies based on experimental validation of a FEM model that was implemented in order to describe the collector-wall system efficiency.
Lingua originale | English |
---|---|
pagine (da-a) | 916-925 |
Numero di pagine | 10 |
Rivista | Energy Procedia |
Volume | 91 |
Stato di pubblicazione | Published - 2016 |
All Science Journal Classification (ASJC) codes
- ???subjectarea.asjc.2100.2100???