Behaviour of Reactive Energy Meters in Polluted Power Systems

Risultato della ricerca: Paper

8 Citazioni (Scopus)

Abstract

The reactive energy meters used in electric distribution networks are based on a conventional definition of reactive energy (or power) for sinusoidal voltages and currents, containing only the fundamental frequency component. As a consequence, the performances of reactive energy meters in the presence of harmonic distortion are not tested and their accuracy specifications can be very different from the nominal ones, that are evaluated in sinusoidal conditions. In this paper the authors present a comparative study of the performances of different reactive energy meters, both electromechanical and static, in the presence of harmonic distortion; the study is supported by several simulations and experimental tests.
Lingua originaleEnglish
Stato di pubblicazionePublished - 2006

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

Cita questo

@conference{f709c43091b147c98d699e8e721f9119,
title = "Behaviour of Reactive Energy Meters in Polluted Power Systems",
abstract = "The reactive energy meters used in electric distribution networks are based on a conventional definition of reactive energy (or power) for sinusoidal voltages and currents, containing only the fundamental frequency component. As a consequence, the performances of reactive energy meters in the presence of harmonic distortion are not tested and their accuracy specifications can be very different from the nominal ones, that are evaluated in sinusoidal conditions. In this paper the authors present a comparative study of the performances of different reactive energy meters, both electromechanical and static, in the presence of harmonic distortion; the study is supported by several simulations and experimental tests.",
keywords = "Reactive power ; Electric potential : power components",
author = "Salvatore Nuccio and Antonio Cataliotti and Valentina Cosentino and Barbaro, {Pietro Vincenzo}",
year = "2006",
language = "English",

}

TY - CONF

T1 - Behaviour of Reactive Energy Meters in Polluted Power Systems

AU - Nuccio, Salvatore

AU - Cataliotti, Antonio

AU - Cosentino, Valentina

AU - Barbaro, Pietro Vincenzo

PY - 2006

Y1 - 2006

N2 - The reactive energy meters used in electric distribution networks are based on a conventional definition of reactive energy (or power) for sinusoidal voltages and currents, containing only the fundamental frequency component. As a consequence, the performances of reactive energy meters in the presence of harmonic distortion are not tested and their accuracy specifications can be very different from the nominal ones, that are evaluated in sinusoidal conditions. In this paper the authors present a comparative study of the performances of different reactive energy meters, both electromechanical and static, in the presence of harmonic distortion; the study is supported by several simulations and experimental tests.

AB - The reactive energy meters used in electric distribution networks are based on a conventional definition of reactive energy (or power) for sinusoidal voltages and currents, containing only the fundamental frequency component. As a consequence, the performances of reactive energy meters in the presence of harmonic distortion are not tested and their accuracy specifications can be very different from the nominal ones, that are evaluated in sinusoidal conditions. In this paper the authors present a comparative study of the performances of different reactive energy meters, both electromechanical and static, in the presence of harmonic distortion; the study is supported by several simulations and experimental tests.

KW - Reactive power ; Electric potential : power components

UR - http://hdl.handle.net/10447/11602

M3 - Paper

ER -