Assessment of the renewable energy production in a historical building for a touristic intended use: a technical-economic feasibility study

Risultato della ricerca: Other

Abstract

This column deals about a study based on technical and economical feasibility of a combination of technologies and systems for energy production concerning electric, heating and cooling to install on a building in the historic centre of a Sicilian city (Italy). After a functional review and an energetic evaluation, the building will have a hotel destination.A first evaluation, made on a model set with the geometrical, thermo-physical and climatic data both of the building and the place, allowed to make a dynamic simulation to define the energetic monthly needs. The evaluation has been done considering different solutions and technologies.With the collected data we supposed a first sizing of the HVAC systems used for the nexteconomical evaluation. We considered the expenses for realization and the energy saved using methods called “Actualized net value” and “Payback Time”. The final analysis shows benefits and disadvantages on each simulations with every kind of technologies used helping us to decide what to use.
Lingua originaleEnglish
Numero di pagine0
Stato di pubblicazionePublished - 2011

Fingerprint

Economics
Electric heating
Hotels
Cooling
Computer simulation
HVAC

Cita questo

@conference{42bf822d81cc4fd493a0e6151e0adcb4,
title = "Assessment of the renewable energy production in a historical building for a touristic intended use: a technical-economic feasibility study",
abstract = "This column deals about a study based on technical and economical feasibility of a combination of technologies and systems for energy production concerning electric, heating and cooling to install on a building in the historic centre of a Sicilian city (Italy). After a functional review and an energetic evaluation, the building will have a hotel destination.A first evaluation, made on a model set with the geometrical, thermo-physical and climatic data both of the building and the place, allowed to make a dynamic simulation to define the energetic monthly needs. The evaluation has been done considering different solutions and technologies.With the collected data we supposed a first sizing of the HVAC systems used for the nexteconomical evaluation. We considered the expenses for realization and the energy saved using methods called “Actualized net value” and “Payback Time”. The final analysis shows benefits and disadvantages on each simulations with every kind of technologies used helping us to decide what to use.",
keywords = "Renewable energy system, economic evaluation, energy saving, environmental evaluation",
author = "Angelo Milone and Daniele Milone and Alessandra Galatioto",
year = "2011",
language = "English",

}

TY - CONF

T1 - Assessment of the renewable energy production in a historical building for a touristic intended use: a technical-economic feasibility study

AU - Milone, Angelo

AU - Milone, Daniele

AU - Galatioto, Alessandra

PY - 2011

Y1 - 2011

N2 - This column deals about a study based on technical and economical feasibility of a combination of technologies and systems for energy production concerning electric, heating and cooling to install on a building in the historic centre of a Sicilian city (Italy). After a functional review and an energetic evaluation, the building will have a hotel destination.A first evaluation, made on a model set with the geometrical, thermo-physical and climatic data both of the building and the place, allowed to make a dynamic simulation to define the energetic monthly needs. The evaluation has been done considering different solutions and technologies.With the collected data we supposed a first sizing of the HVAC systems used for the nexteconomical evaluation. We considered the expenses for realization and the energy saved using methods called “Actualized net value” and “Payback Time”. The final analysis shows benefits and disadvantages on each simulations with every kind of technologies used helping us to decide what to use.

AB - This column deals about a study based on technical and economical feasibility of a combination of technologies and systems for energy production concerning electric, heating and cooling to install on a building in the historic centre of a Sicilian city (Italy). After a functional review and an energetic evaluation, the building will have a hotel destination.A first evaluation, made on a model set with the geometrical, thermo-physical and climatic data both of the building and the place, allowed to make a dynamic simulation to define the energetic monthly needs. The evaluation has been done considering different solutions and technologies.With the collected data we supposed a first sizing of the HVAC systems used for the nexteconomical evaluation. We considered the expenses for realization and the energy saved using methods called “Actualized net value” and “Payback Time”. The final analysis shows benefits and disadvantages on each simulations with every kind of technologies used helping us to decide what to use.

KW - Renewable energy system

KW - economic evaluation

KW - energy saving

KW - environmental evaluation

UR - http://hdl.handle.net/10447/56296

M3 - Other

ER -