A two-end traveling wave fault location system for MV Cables

Eleonora Riva Sanseverino, Vincenzo Li Vigni, Roberto Candela, Antonio Di Stefano

Risultato della ricerca: Article

Abstract

In this paper, a new low-cost device is proposed for fault location in power distribution system. The device is part of a system that should include several units installed in couples at the two ends of medium voltage (MV) cable lines. Their low cost justifies a widespread installation of these devices, moreover other functionalities could be considered so as to enrich the potential of the system for MV cables monitoring and asset management. The system exploits a two-end traveling wave technique, low complexity, and low-cost solutions both for the analog front end as well as for the communication infrastructure. A LoRa network is indeed considered as wireless modulation technique perfectly suited when communication links with three characteristics are needed: low power, low bit rate, and long range. This paper shows the device that has been set up in Prysmian Electronics with some experimental phases showing the effectiveness of the proposed solution and the further developments expected.
Lingua originaleEnglish
pagine (da-a)1180-1188
Numero di pagine9
RivistaIEEE Transactions on Industry Applications
Volume55
Stato di pubblicazionePublished - 2019

Fingerprint

Electric fault location
Cables
Electric potential
Costs
Asset management
Telecommunication links
Electronic equipment
Modulation
Monitoring
Communication

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Cita questo

A two-end traveling wave fault location system for MV Cables. / Riva Sanseverino, Eleonora; Li Vigni, Vincenzo; Candela, Roberto; Di Stefano, Antonio.

In: IEEE Transactions on Industry Applications, Vol. 55, 2019, pag. 1180-1188.

Risultato della ricerca: Article

Riva Sanseverino, Eleonora ; Li Vigni, Vincenzo ; Candela, Roberto ; Di Stefano, Antonio. / A two-end traveling wave fault location system for MV Cables. In: IEEE Transactions on Industry Applications. 2019 ; Vol. 55. pagg. 1180-1188.
@article{fd54799f10a649a19290b0415dbce5cc,
title = "A two-end traveling wave fault location system for MV Cables",
abstract = "In this paper, a new low-cost device is proposed for fault location in power distribution system. The device is part of a system that should include several units installed in couples at the two ends of medium voltage (MV) cable lines. Their low cost justifies a widespread installation of these devices, moreover other functionalities could be considered so as to enrich the potential of the system for MV cables monitoring and asset management. The system exploits a two-end traveling wave technique, low complexity, and low-cost solutions both for the analog front end as well as for the communication infrastructure. A LoRa network is indeed considered as wireless modulation technique perfectly suited when communication links with three characteristics are needed: low power, low bit rate, and long range. This paper shows the device that has been set up in Prysmian Electronics with some experimental phases showing the effectiveness of the proposed solution and the further developments expected.",
author = "{Riva Sanseverino}, Eleonora and {Li Vigni}, Vincenzo and Roberto Candela and {Di Stefano}, Antonio",
year = "2019",
language = "English",
volume = "55",
pages = "1180--1188",
journal = "IEEE Transactions on Industry Applications",
issn = "0093-9994",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - JOUR

T1 - A two-end traveling wave fault location system for MV Cables

AU - Riva Sanseverino, Eleonora

AU - Li Vigni, Vincenzo

AU - Candela, Roberto

AU - Di Stefano, Antonio

PY - 2019

Y1 - 2019

N2 - In this paper, a new low-cost device is proposed for fault location in power distribution system. The device is part of a system that should include several units installed in couples at the two ends of medium voltage (MV) cable lines. Their low cost justifies a widespread installation of these devices, moreover other functionalities could be considered so as to enrich the potential of the system for MV cables monitoring and asset management. The system exploits a two-end traveling wave technique, low complexity, and low-cost solutions both for the analog front end as well as for the communication infrastructure. A LoRa network is indeed considered as wireless modulation technique perfectly suited when communication links with three characteristics are needed: low power, low bit rate, and long range. This paper shows the device that has been set up in Prysmian Electronics with some experimental phases showing the effectiveness of the proposed solution and the further developments expected.

AB - In this paper, a new low-cost device is proposed for fault location in power distribution system. The device is part of a system that should include several units installed in couples at the two ends of medium voltage (MV) cable lines. Their low cost justifies a widespread installation of these devices, moreover other functionalities could be considered so as to enrich the potential of the system for MV cables monitoring and asset management. The system exploits a two-end traveling wave technique, low complexity, and low-cost solutions both for the analog front end as well as for the communication infrastructure. A LoRa network is indeed considered as wireless modulation technique perfectly suited when communication links with three characteristics are needed: low power, low bit rate, and long range. This paper shows the device that has been set up in Prysmian Electronics with some experimental phases showing the effectiveness of the proposed solution and the further developments expected.

UR - http://hdl.handle.net/10447/376660

M3 - Article

VL - 55

SP - 1180

EP - 1188

JO - IEEE Transactions on Industry Applications

JF - IEEE Transactions on Industry Applications

SN - 0093-9994

ER -