TY - JOUR
T1 - A Multicenter International Randomized Controlled Manikin Study on Different Protocols of Cardiopulmonary Resuscitation for Laypeople: The MANI-CPR Trial
AU - Giarratano, Antonino
AU - Cortegiani, Andrea
AU - Pugliesi, Marinella
AU - Dénéréaz, Sandrine
AU - Ferraro, Ottavia Eleonora
AU - Cortegiani, Andrea
AU - Baldi, Enrico
AU - Bertaia, Daniele
AU - Contri, Enrico
AU - Borrelli, Paola
AU - Burkart, Roman
AU - Terrapon, Michael
AU - Tami, Christian
AU - Boldarin, Susi
AU - Lopez, Daniel
AU - Paglino, Martina
AU - Cortegiani, Andrea
AU - Barbati, Chiara
AU - Montalto, Francesca
AU - Pugliesi, Marinella
AU - Iozzo, Pasquale
PY - 2020
Y1 - 2020
N2 - Background: Compression-only cardiopulmonary resuscitation (CPR) is a suggested technique for laypeople facing out-of-hospital cardiac arrest (OHCA). However, it is difficult performing high-quality CPR until emergency medical services arrival with this technique. We aimed to verify whether incorporating intentional interruptions of different frequency and duration increases laypeople's CPR quality during an 8-minute scenario compared with compression-only CPR.Methods: We performed a multicenter randomized manikin study selecting participants from 2154 consecutive laypeople who followed a basic life support/automatic external defibrillation course. People who achieved high-quality CPR in 1-minute test on a computerized manikin were asked to participate. Five hundred seventy-six were enrolled, and 59 were later excluded for technical reasons or incorrect test recording. Participants were randomized in an 8-minute OHCA scenario using 3 CPR protocols (30 compressions and 2-second pause, 30c2s; 50 compressions and 5-second pause, 50c5s; 100 compressions and 10-second pause, 100c10s) or compression-only technique. The main outcome was the percentage of chest compressions with adequate depth.Results: Five hundred seventeen participants were evaluated. There was a statistically significant difference regarding the percentage of compressions with correct depth among the groups (30c2s, 96%; 50c5s, 96%; 100c10s, 92%; compression only, 79%; P = 0.006). Post hoc comparison showed a significant difference for 30c2s (P = 0.023) and for 50c5s (P = 0.003) versus compression only. Regarding secondary outcome, there were a higher chest compression fraction in the compression-only group and a higher rate of pauses longer than 10 seconds in the 100c10s.Conclusions: In a simulated OHCA, 30c2s and 50c5s protocols were characterized by a higher rate of chest compressions with correct depth than compression only. This could have practical consequences in laypeople CPR training and recommendations.
AB - Background: Compression-only cardiopulmonary resuscitation (CPR) is a suggested technique for laypeople facing out-of-hospital cardiac arrest (OHCA). However, it is difficult performing high-quality CPR until emergency medical services arrival with this technique. We aimed to verify whether incorporating intentional interruptions of different frequency and duration increases laypeople's CPR quality during an 8-minute scenario compared with compression-only CPR.Methods: We performed a multicenter randomized manikin study selecting participants from 2154 consecutive laypeople who followed a basic life support/automatic external defibrillation course. People who achieved high-quality CPR in 1-minute test on a computerized manikin were asked to participate. Five hundred seventy-six were enrolled, and 59 were later excluded for technical reasons or incorrect test recording. Participants were randomized in an 8-minute OHCA scenario using 3 CPR protocols (30 compressions and 2-second pause, 30c2s; 50 compressions and 5-second pause, 50c5s; 100 compressions and 10-second pause, 100c10s) or compression-only technique. The main outcome was the percentage of chest compressions with adequate depth.Results: Five hundred seventeen participants were evaluated. There was a statistically significant difference regarding the percentage of compressions with correct depth among the groups (30c2s, 96%; 50c5s, 96%; 100c10s, 92%; compression only, 79%; P = 0.006). Post hoc comparison showed a significant difference for 30c2s (P = 0.023) and for 50c5s (P = 0.003) versus compression only. Regarding secondary outcome, there were a higher chest compression fraction in the compression-only group and a higher rate of pauses longer than 10 seconds in the 100c10s.Conclusions: In a simulated OHCA, 30c2s and 50c5s protocols were characterized by a higher rate of chest compressions with correct depth than compression only. This could have practical consequences in laypeople CPR training and recommendations.
UR - http://hdl.handle.net/10447/434159
M3 - Article
SN - 1559-2332
VL - Publish Ahead of Print
JO - Simulation in Healthcare
JF - Simulation in Healthcare
ER -