A Method to Reduce the FP/imm Number ThroughCC and MLO Views Comparison in MammographicImages

Rosario Magro, Donato Cascio, Liliana Lo Presti, Giuseppe Raso, Salvatore Sorce, Marius Iacomi, Cascio, Lenzi, Maria Simone Vasile, Raso, Francesco Fauci, Magro, Marius Mihail Iacomi

Risultato della ricerca: Otherpeer review

2 Citazioni (Scopus)

Abstract

In this paper we propose a method to reduce the FP/imm number through CC and MLO mammographic views comparison of the same patient. The proposed solution uses the symmetry properties of the breast to compute a geometric transformation that permits to represent the two images in comparable coordinates systems. Through this method, potential pathological ROIs of one of the projections are correlated with the ROIs in the second view. To show the effectiveness of the result we apply the method on a dataset composed of 112 couples of pathological images. Experiments shows that method enables a reduction by up to 700/0 of the FP/imm number detected after the classification step
Lingua originaleEnglish
Pagine4364-4367
Numero di pagine4
Stato di pubblicazionePublished - 2009

All Science Journal Classification (ASJC) codes

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Fingerprint Entra nei temi di ricerca di 'A Method to Reduce the FP/imm Number ThroughCC and MLO Views Comparison in MammographicImages'. Insieme formano una fingerprint unica.