Abstract
A complete innovative measurement system (D2SI - device for the diagnosis of insulation systems) for both acquisition, analysis and processing of partial discharge signals generated in insulation systems under voltage stress (IEC standard), was designed and realized; several measurements on practical insulation systems demonstrated the full and correct equipment operation.
Lingua originale | English |
---|---|
Titolo della pubblicazione ospite | 2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA |
Pagine | 481-484 |
Numero di pagine | 4 |
Stato di pubblicazione | Published - 2004 |
All Science Journal Classification (ASJC) codes
- ???subjectarea.asjc.2200.2200???