Abstract
The paper presents a bottom-up approach for building the aggregated load profile of numerous passive/active users connected to the low voltage electrical system. The approach is based on the Monte Carlo method and on the knowledge of the single electric and thermal loads, generators and thermal and geometrical characteristics of the building of the single end-user. The method proposed is able to differentiate the quota of flexible and not flexible aggregate load.
Lingua originale | English |
---|---|
Titolo della pubblicazione ospite | Proceedings of 15th IEEE International Conference on Environment and Electrical Engineering - EEEIC 2015 |
Pagine | 542-547 |
Numero di pagine | 6 |
Stato di pubblicazione | Published - 2015 |
All Science Journal Classification (ASJC) codes
- ???subjectarea.asjc.2200.2208???
- ???subjectarea.asjc.2100.2102???