TY - JOUR
T1 - Wireless partial discharge tracking on cross-linked polyethylene MV and HV cables
AU - Riva Sanseverino, Eleonora
AU - Madonia, Antonino
AU - Romano, Pietro
AU - Mazzanti, Giovanni
AU - Troia, Ivan
AU - Albertini, Marco
AU - Giannini, Simone
AU - Albertini, Marco
AU - Mazzanti, Giovanni
AU - Bononi, Stefano Franchi
PY - 2018
Y1 - 2018
N2 - Medium voltage (MV)/high voltage (HV) cable lines are high-value assets and require substantial costs for their installation or replacement. For this reason, the capability to assess the condition of cable lengths and accessories on site is of great importance. Cross-linked polyethylene (XLPE) insulation is extensively used for MV, HV, and extra-high voltage (EHV) class cables [1] thanks to its excellent voltage-endurance and thermomechanical properties. In particular, XLPE-insulated cables feature substantially lower losses, easier manufacturing and jointing procedures, better environmental compatibility, and higher operating temperature compared with impregnated paper cables, which lead to lower costs in procurement and operation [2], [3].
AB - Medium voltage (MV)/high voltage (HV) cable lines are high-value assets and require substantial costs for their installation or replacement. For this reason, the capability to assess the condition of cable lengths and accessories on site is of great importance. Cross-linked polyethylene (XLPE) insulation is extensively used for MV, HV, and extra-high voltage (EHV) class cables [1] thanks to its excellent voltage-endurance and thermomechanical properties. In particular, XLPE-insulated cables feature substantially lower losses, easier manufacturing and jointing procedures, better environmental compatibility, and higher operating temperature compared with impregnated paper cables, which lead to lower costs in procurement and operation [2], [3].
KW - Optical and Magnetic Materials; Electrical and Electronic Engineering
KW - cable insulation; cross-linked polyethylene insulation; fault diagnosis; fault location; partial discharge; power cable; power cable testing; Electronic
KW - Optical and Magnetic Materials; Electrical and Electronic Engineering
KW - cable insulation; cross-linked polyethylene insulation; fault diagnosis; fault location; partial discharge; power cable; power cable testing; Electronic
UR - http://hdl.handle.net/10447/344201
M3 - Article
SN - 0883-7554
VL - 34
SP - 8
EP - 17
JO - IEEE Electrical Insulation Magazine
JF - IEEE Electrical Insulation Magazine
ER -