Abstract
This paper presents the evaluation of the metrological performances of a DAQ-based sampling wattmeter (DAQ-SW) for the measurement of IEEE Std. 1459-2010 power quantities in non-sinusoidal conditions. The instrument makes use of two commercial data acquisition (DAQ) boards, a non-inductive current shunt, a personal computer and a commercial software for data processing. Starting from the results of an experimental characterization of the two instrument channels with non-sinusoidal voltages and currents and a correlationanalysis, the combined standard uncertainties of IEEE Std. 1459-2010 quantities are evaluated, following the approach of the ISO Guide to the Expression of Uncertainty in Measurement (GUM).
Original language | English |
---|---|
Pages (from-to) | 27-38 |
Number of pages | 12 |
Journal | Measurement |
Volume | 61 |
Publication status | Published - 2015 |
All Science Journal Classification (ASJC) codes
- Instrumentation
- Electrical and Electronic Engineering